PRODUCTS 
 TECHNICAL INFO 
 PARTNER & AGENCY 
 CLIENTS 

 

explosion proof temperature sensor
Thermocouple assemblies
High temperature assemblies
RTD assemblies
Thermo well & protection tube
Temperature transmitter & controllers
Bimetal Temperature gauge
Instrument cable
 

 

 

 

 

Mineral Insulated Cable

We are submitted kind of Mineral Insulated  cables

The construction of a mineral insulated cable is as follows:
- one or more wire- like conductors (cores) are embedded in a high insulation quality mineral powder and pressed into a metal tube (sheath) made of oxidation and corrosion resistant material. The entire material combination is then processed using suitable forming steps to obtain the final dimensions.

There are two groups:

 Mineral Insulated Thermocouple Cables

The inner conductors consist of one or more thermocouples for temperature measurement. There, we are dealing with a sheathed thermocouple conductor. The compensation conductor which extends the thermocouple from the point of connection to the reference junction can also be insulated in the same manner.

 Mineral Insulated Measurement Cables

The inner conductor is generally a low resistive wire (in some cases several wires) which transmits the electrical signal. Conductors of this type are used in measurement and control techniques and thus referred to as sheathed measurement conductors.

Extension Thermocouples cable

compensating thermocouples cable

Measuring cable

 

FIRE WALL CABLE

 

Number of conductors Inner conductor Insulation Sheat material
1 1 core C              cooper 1   AI²O³ (97%) A 1.4541
2 2 cores Ni               nickel 2    MgO (96%) F 1.4571
4 4 cores CN  cooper-nickel 3  MgO(99,4%) L 2.4816
6 6 cores CNi   nickel plated copper   P 2.4951  
      Q 1.4845
      R 1.4301
      S 1.4404
      X other qualities
Other types on on request e.g. "wide space".

Example: The type Denotation 2C2A60 designates a cable coil with 2 cores, inner conductors made of cooper, insulation made of MgO (96%), the sheat material 1.4541 and an outer diameter of 6

BS MI Wiring Cable

BICC Thermoheat

Mineral Insulated wiring cable has provided the solution to many wiring problems. The construction has remained practically unchanged for over 75 years, with improvements and refinements centred on materials and processing.
  One or more conductors are embedded in dense mineral insulation, protected and contained by a tubular metallic outer sheath.
  This inorganic construction ensures a unique combination of electrical safety, mechanical strength and durability and a flexibility that enables ease of installation and an aesthetic presentation when installed.

 

 

 

 

 

a

TEMPRATURE SENSORE

PRESSURE

FLOW

LEVEL

OTHER PRODUCT

Bimetal Temperature gauge
Temperature transmitter & controller
Thermocouple assemblies
High temperature assemblies
RTD assemblies
Thermo well & protection tube
Instrument cable
Pressure gauge
Pressure transmitter
DP transmitter
Pressure swith
Flow indicator
Flow sensor
Flow transmitter
Thermal mass Flow meter
Ultrasonic Flow meter
Magnetic vortex Flow meter
variable area Flow meter


Ultrasonic Level meter
Level transmitter
Level swith

Heat tracing cable & accessories
Heating element
Ceramics
Accessories of Temperature

ABOUT US
PRODUCTS
CONTACT US
THECNICAL INFO
PARTNER & AGENCY
CLIENTS